TELEHOUSE 2000
This
project was installed and is being maintained by us. The buildings were purpose
built data storage & Internet hub, complete with administrative offices.
Due to the nature of the facility, the lifts had to be linked to the buildings' remote diagnostic system which includes all services in the buildings. We also had to use security card readers to replace the push buttons on the landings.

The
glass lift serves two floors and is driven by a single direct acting ram located
under the lift car extending into a borehole. The surrounding area was then
clad in specialist material to the client choice. This hid most of the lift
workings and is easily removable during maintenance.
All the glass for the shaft and car were designed, manufactured and installed by us, assembled in our factory for acceptance by the client prior to the site installation.
There
are four other lifts installed on this project. These include two fire fighting
lifts, fully compliant with BS5588, one heavy duty goods lift and a scissors
lift.
The fire fighting lifts
have a contract capacity of 10 persons / 800Kg. They are designed to include
specialist intercom systems for the use by the fire brigade and all equipment
is resistant to water.
The goods lift has a contract capacity to suit either 26 persons / 2000 Kg. The car is of a full metal construction, which offers the most robust finishes for the lift's duty

The scissors lift is located in the external loading bay and is rated to carry 2000Kg.
Due to it's location, the materials used are weather resistant (galvanised) to reduce the possibility of corrosion.
Copyright © 2001 Elite Elevators Group. All rights reserved